CS Instruments LD 300 Instrukcja Obsługi Strona 5

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 4
CS Instruments
- 5 -
Technical data
Operating frequency: 40 kHz ±2 kHz
Plugs: 1) 4 pole connector shared by
headphone and battery charger
2) 3.5mm stereo phone jack for sensor or
sensor cable connection.
Display: 3 colour black-mask LCD, 10 level
LASER pointer: 640 ... 660 nm wavelength
0.4.0.5 mW output power
Power supply: Internal NiMH rechargeable battery
Operating time: about 6 hours without LASER pointer on
about 4 hours with LASER pointer on
Charging time: around 1.5 hour
Charging operation temp.: +10°C to + 45°C (recommended)
Operating temperature: 0°C to + 40°C
Storage temperature: -10°C to + 50°C
Weight: 2.5 kg (full set)
Performance chart
It shows the detection distance of various hole diameters at different
pressures (lab environment).
Pressure / diameter
0.1 mm
0.2 mm
0.5 bar
2 m
2 m
5.0 bar
8 m
14 m
Attention:
The sensor unit can be unplugged from the main instrument by pulling the
unit out of the holder. A separate coiled extension cable is used to connect
the sensor to the main unit.